活动板房不需要像我们通常居住的那样大。装修,但是,在生活的过程中根据其建筑特点,它须遵循简单和灵活的原则来改造或装饰。下面来讲述下讲述
济南活动板房设计布局的注意事项。
The prefabricated houses do not need to be as big as those we usually live in. Decoration, however, in the process of life, according to its architectural characteristics, it must follow the principles of simplicity and flexibility to transform or decorate. Now let's talk about the precautions for the design and layout of movable plank houses in Jinan.
活动板房与建筑物类似,好用钢筋混凝土平整周围和隔墙,更坚固;然后柱子与横梁连接骨架,上隔板,外墙板和门窗框架;然后铺设地板,然后安装上层,然后安装屋顶框架和屋顶板;后,安装门窗,拉动垂直支撑。它是卫生洁具,硬件等。
The prefabricated house is similar to the building, and it is easy to use reinforced concrete to level the surrounding and partition walls, which is more solid; Then the column and beam connect the skeleton, upper partition, exterior wall panel and door and window frame; Then lay the floor, then install the upper layer, and then install the roof frame and roof slab; After that, install the door and window and pull the vertical support. It is sanitary ware, hardware, etc.
1、墙板应正确进行安装,表面具有光滑;嵌入式以及墙板应平放,顶部和底部搭接接头应连接,外板重叠,搭接长度一般不小于15mm。
1. The wallboard shall be installed correctly with smooth surface; Embedded and wall panels shall be placed horizontally, the top and bottom lap joints shall be connected, and the outer panels shall be overlapped, with the lap length generally not less than 15mm.
2、活动板房电路应为PVC管(槽),线路整齐美观;电气设备配置是否符合教学设计发展要求;线路问题没有绝缘和老化。
2. The circuit of movable plank house shall be PVC pipe (groove), and the circuit shall be neat and beautiful; Whether the electrical equipment configuration meets the development requirements of teaching design; There is no insulation or aging in the circuit.
3、活动结构板房的维护板(屋顶板和墙板)不应有明显的变形或损坏;固定一个螺栓,防水垫圈,金属垫圈,尼龙套,连接进行可靠;密封胶是完整科学有效的。
3. The maintenance board (roof board and wall board) of the movable structure board room should not have obvious deformation or damage; Fix a bolt, waterproof washer, metal washer, nylon sleeve, and connect reliably; The sealant is complete, scientific and effective.
4、火灾间距应符合设计和规范要求,火灾出口应平稳;消防栓和灭火器应按照设计要求和合理的布局进行布置。厨房的防火保温措施应当有效。耐火金属夹层板氧指数不小于32,木地板等易燃材料应防火。
4. The fire spacing shall meet the design and specification requirements, and the fire exit shall be stable; Fire hydrants and fire extinguishers shall be arranged according to design requirements and reasonable layout. The fire prevention and thermal insulation measures of the kitchen shall be effective. The oxygen index of fire-resistant metal sandwich plate shall not be less than 32, and the wood floor and other flammable materials shall be fireproof.
In addition, after a period of use, there will be some loose parts of prefabricated houses, especially in the rainy season, which are more likely to cause problems. Therefore, it is necessary to check the spare parts of the mobile room after it has been used for a period of time. More relevant content will come to our website http://www.lxcaigang.com Consult!