当单面坡长小于12m时,屋面可不设横缝;当单面坡长大于12m时,彩钢板间需设横缝搭接。横缝一般采用顺水搭接,为保证防水效果,必须满足一定的搭接长度,且搭接长度长短与屋面坡度有关,当坡度小于等于1/10时,一般不宜小于300mm;当坡度大于1/10时,一般不宜小于200mm,并要求在搭接处高低错开,上下两层板之间粘贴防水密封胶条。
When the single slope length is less than 12M, the roof can not be set with transverse joints; when the slope length of one side is greater than 12M, transverse joints should be set between color steel plates. The transverse joints are generally overlapped along the water. To ensure the waterproof effect, a certain lap length must be met, and the length of the lap length is related to the roof slope. When the slope is less than or equal to 1 / 10, it should not be less than 300 mm; when the slope is greater than 1 / 10, it should not be less than 200 mm. The height of the lap joint should be staggered, and the waterproof sealant strip should be pasted between the upper and lower plates.
这样不仅可有效防止渗水,还可防止彩钢板切口处氧化锈蚀。同时应注意搭接处一般采用自攻螺钉固定在波峰位置。若设置在波谷上,必须要有可靠的防水措施。
This can not only effectively prevent water seepage, but also prevent oxidation and corrosion at the cut of color steel plate. At the same time, it should be noted that the lap joint is generally fixed in the wave crest position with self tapping screws. If it is set on the trough, reliable waterproof measures must be taken.
屋面低波彩钢板用连接件直接与檩条连接,每波或隔一个波设置一个,但搭接波处必须设置连接件。屋面高波彩钢板用连接件与固定支架连接,每波设置一个。另一种上下板连接方法是压板挤紧法,在两块彩钢板的上面和下面各设一块与彩钢板板型相同的镀锌钢板,两板间设防水密封条,用紧固螺栓将其紧密挤压连接在一起。
Roof low wave color steel plate is directly connected with purlin by connectors, one for each wave or every other wave, but connectors must be set at overlapping wave. The roof high wave color steel plate is connected with the fixed support by connecting pieces, one for each wave. Another method of connecting the upper and lower plates is the pressing plate pressing method. A galvanized steel plate with the same type as the color steel plate is set at the top and bottom of the two color steel plates, and the waterproof sealing strip is set between the two plates, which are tightly squeezed together by the fastening bolts.
为避免板的长向搭接处引起漏水,也可将压型板生产设备运现场安装,轧制从屋脊到檐口的整张屋面板,边轧制边安装,无需长向搭接,避免不必要的渗漏。通常情况下,选用长板不搭接更好,但在实际工程中发现,板过长时,由于温度影响板的伸缩会引起螺孔扩张而产生渗漏;同时,由于板过长,在制造、运输或施工过程中易损伤涂层,影响质量。
In order to avoid water leakage caused by the long-term lap joint of the plate, the profiled plate production equipment can also be transported to the site for installation. The whole roof panel from the roof ridge to the cornice can be rolled and installed while rolling. There is no need for long-term lapping to avoid unnecessary leakage. In general, it is best to choose the long plate without overlapping, but it is found in the actual project that when the plate is too long, the expansion of screw hole will be caused due to the influence of temperature on the expansion of screw hole; at the same time, because the plate is too long, it is easy to damage the coating in the process of manufacturing, transportation or construction, and affect the quality.