随着城市的发展,城市中在建施工工地随处可见,建筑工地中,活动板房是施工工人临时居住搭建的建筑,但近年来活动板房发生的火灾也屡见不鲜,值得大家注意。
With the development of the city, construction sites under construction can be seen everywhere in the city. In construction sites, movable plank houses are buildings built for temporary residence of construction workers, but fires in movable plank houses are also common in recent years, which is worthy of attention.
活动板房消防应注意以下四个方面:
The following four aspects shall be paid attention to in fire fighting of movable plank house:
1、活动板房在设计彩钢板建筑时,要严格执行标准规范要求,新建、扩建、改建使用彩钢板的厂房、仓库、商店等建设工程和用作人员密集场所的临时性建筑,从源头加强彩钢板建筑的消防管理。
1. When designing color steel plate buildings, the movable plate houses shall strictly comply with the requirements of standards and specifications, build, expand and reconstruct construction projects such as workshops, warehouses and stores using color steel plates and temporary buildings used as densely populated places, and strengthen the fire control management of color steel plate buildings from the source.
2、加强活动板房的日常消防管理,板房内禁止使用大功率电器,离开房间时及时断掉多有电源,禁止在房间内使用明火,禁止将活动板房作为厨房、配电房、易燃易爆用品库房等使用。
2. Strengthen the daily fire control management of the movable board room. It is forbidden to use high-power electrical appliances in the board room. When leaving the room, cut off many power supplies in time. It is forbidden to use open fire in the room. It is forbidden to use the movable board room as a kitchen, power distribution room, inflammable and explosive warehouse, etc.
3、活动板房的电器线路的敷设必须符合规范要求,所有电线应明敷,并套以阻燃管,灯具与墙壁应保持距离,照明日光灯应使用电子镇流器型,不能采用线圈电感式镇流器,电线穿过彩钢板夹芯板墙壁时,必须套不燃塑管,每栋板房都要安装合格的漏电保护装置和短路过载开关。
3. The laying of electrical circuits in the movable board room must meet the specification requirements. All wires shall be laid in the open and covered with flame retardant tubes. The distance between lamps and walls shall be maintained. The lighting fluorescent lamps shall use electronic ballasts instead of coil inductive ballasts. When the wires pass through the walls of color steel sandwich panels, they must be covered with non combustible plastic tubes, Each plank house shall be equipped with qualified leakage protection devices and short-circuit overload switches.
4、当活动板房作为宿舍时,门窗均应向外开启,床铺的摆放不应过于密集,要留出通道,配备充足数量的灭火器,安装室内消火栓,并保证水流量与压力达到相关要求。
4. When the movable board room is used as the dormitory, the doors and windows shall be opened outward, the beds shall not be placed too densely, the passage shall be reserved, a sufficient number of fire extinguishers shall be equipped, indoor fire hydrants shall be installed, and the water flow and pressure shall meet the relevant requirements.
以上就是小编为大家介绍的关于活动板房的相关内容,希望介意帮助到您。更多精彩内容可以直接关注http://www.lxcaigang.com
The above is what Xiaobian introduced to you about the activity board room. I hope I would mind helping you. More exciting content can be directly concerned http://www.lxcaigang.com