您好,欢迎访问禹城泰瑞彩钢复合板加工厂!

服务热线

18765446878

热门关键词:禹城彩钢厂,禹城彩钢复合板,禹城钢结构板房 彩钢板房
当前位置:首页>新闻资讯>新闻动态彩钢板房漏雨怎么办?

彩钢板房漏雨怎么办?

来源:http://www.lxcaigang.com 日期:2022-04-11 发布人:
彩钢板房漏雨怎么办?很多的年岁长的彩钢板房都出现了漏雨的现象,那么彩钢板房漏雨怎么办?其实不同原因导致的漏雨解决方法也不一样的,下面就跟随小编一起来了解下吧!
What if the color steel plank house leaks rain? How can we deal with the phenomenon that the color steel houses leak for so long? In fact, the solutions to rain leakage caused by different reasons are also different. Let's follow Xiaobian to understand it!
一、彩钢板房结构厂房屋脊部位漏水
1、 There is water leakage at the ridge of the workshop with color steel plate house structure
1、主要原因:屋脊处波峰太高,屋脊盖板无法保证防水;纵向搭接不放胶泥或硅胶,形成缝隙而漏水;屋脊盖板纵向搭接用铆钉连接,热胀冷缩强度不够而拉断铆钉,形成漏水;活动板房屋脊盖板与屋面板之间不敷设堵头,或堵头放置不规范而脱落形成漏水。
1. Main reasons: the crest at the ridge is too high, and the ridge cover plate can not ensure waterproof; Longitudinal lapping without mastic or silica gel, forming a gap and water leakage; The ridge cover plate is longitudinally overlapped and connected with rivets, and the rivets are broken due to insufficient strength of thermal expansion and cold contraction, resulting in water leakage; No plug is laid between the ridge cover plate and the roof slab of the movable plank house, or the plug is placed irregularly and falls off to form water leakage.
2、解决办法:屋脊盖板做宽些,另外坡度找大点;搭接处敷设胶泥或硅胶;更换缝合钉;堵头应与板型板匹配,堵头敷设时应上下放胶泥或硅胶。
2. Solution: make the ridge cover wider, and find a larger slope; Lay mastic or silica gel at the lap joint; Replace the suture nail; The plug shall match the plate type plate, and the mastic or silica gel shall be put up and down when the plug is laid.
二、彩钢板房结构厂房屋面檐口部位漏水
2、 There is water leakage at the cornice of the roof of the color steel plate house structure plant
1、主要原因:屋面外板安装未加泡沫堵头,屋面外板未下扳;墙面外板长度不足,且檐口部位未加防水收边。
1, the main reason is: the roof outer panel is not installed with foam plug, and the roof outer panel is not pulled down. The length of the outer plate of the wall is insufficient, and the cornice is not provided with waterproof trimming.
2、解决办法:屋面外板安装时应同时放置泡沫堵头,且将屋面外板下扳30度;檐口处应按现设计情况增设收边。
2, solution: when the roof is installed, foam plugs should be placed at the same time, and the roof should be pulled down for 30 degrees. Edge trimming shall be added at the cornice according to the current design.
三、彩钢板房结构厂房屋面开孔部位漏水
3、 There is water leakage at the roof opening of the color steel plate house structure plant
1、主要原因:风机开孔未按设计节点进行防水处理,钢堵头放置未敷设防水胶泥和硅胶;风机开孔四周预留范围较小,雨水流淌不畅,容易积水;开孔四周包边搭接未进行防水处理;开孔内部四周未加结构件,形成低凹积水;
1. Main reasons: the fan opening is not waterproof according to the design node, and the steel plug is not laid with waterproof mastic and silica gel; The reserved range around the fan opening is small, the rainwater flow is not smooth, and it is easy to accumulate water; No waterproof treatment is carried out for the edge wrapping and overlapping around the opening; No structural parts are added around the opening, forming low concave ponding;
2、解决办法:须按设计图纸施工并严格施工工序,敷设胶泥、硅胶;风机四周预留范围需要满足排水要求;墙面、屋面开孔后需要随后进行防水处理;后增围护开孔尽量要增设檩条或角钢结构,减小围护变形;防水安装需要严密、平整,使水流顺畅。
2. Solution: the construction shall be carried out according to the design drawings and the construction process shall be strictly followed, and the mastic and silica gel shall be laid; The reserved area around the fan shall meet the drainage requirements; Waterproof treatment shall be carried out after the opening of wall and roof; Purlin or angle steel structure shall be added as much as possible to reduce enclosure deformation; The waterproof installation shall be tight and flat to make the water flow smooth.
四、彩钢板房结构厂房屋面气楼部位漏水:
4、 Water leakage at the roof air tower of color steel plate house structure workshop:
1、主要原因:气楼与屋面交接处收边下未放置泡沫堵头,且收边纵向搭接未敷设胶泥或硅胶;屋面外板在气楼交接处未上板;气楼结构支柱开孔部位未做防水处理;气楼自身制作、安装存在漏水隐患。
1, the main reason is: no foam plug is placed at the junction of the building and the roof, and no glue or silica gel is laid on the side. The roof outer plate is not installed at the junction of the air tower; The opening part of the pillar of the air tower structure is not waterproof; There are hidden dangers of water leakage in the manufacture and installation of the gas tower itself.
2、解决办法:收边安装前应敷设泡沫堵头,纵向搭接须设置胶泥或堵头并用缝合钉固定;气楼安装前需要将屋面板上扳;要求气楼施工方在气楼结构完成后需要将开孔部位进行防水处理;对气楼安装质量和防水性进行查验。
2, solution: foam plugs should be laid before installation and installation. The roof panel shall be pulled up before the installation of the gas tower; The Construction Party of the gas building is required to conduct waterproof treatment on the opening part after the completion of the gas building structure; Check the installation quality and waterproof of the air tower.
以上就是为大家介绍的有关济南彩钢板房的详细介绍,希望对您有所帮助.如果您有什么疑问的话,欢迎联系我们.我们将以的态度,为您提供服务http://www.lxcaigang.com
The above is the detailed introduction of Jinan color steel plank house. I hope it will be helpful to you If you have any questions, please contact us We will provide you with professional service http://www.lxcaigang.com

联系电话:18765446878

咨询热线:18765446878(微信同号)

地址:禹城市十里望镇山东国际商贸港往南660米