活动房的布局是很有讲究的,不是随随便便就可以搭建的。安徽活动房厂家今天来与您分享一些活动房布局时的注意事项,希望对您起到一些帮助。
The layout of the activity room is very particular, which can not be built casually. Anhui mobile house manufacturers are here today to share with you some precautions for the layout of mobile houses, hoping to help you.
1、活动房围护板材(屋面板和墙板)应无明显变形、损坏;固定螺栓、防水垫圈、金属垫圈、尼龙套管等齐全,连接可靠;密封胶齐全。
1. The enclosure plate (roof panel and wall panel) of the movable room shall be free from obvious deformation and damage; Fixing bolts, waterproof washers, metal washers, nylon sleeves, etc. are complete and connected reliably; Sealant is complete.
2、活动房屋面板应安装平稳、檐口平直,板的搭接方向正确一致。
2. The panel of movable house shall be installed stably, the cornice shall be straight, and the overlapping direction of the panel shall be correct and consistent.
3、附着式墙板安装应排板正确,表面平整;嵌入式墙板安装应平整,上下搭接缝应采用企口缝,外侧板应向下搭接,搭接长度不小于15mm。
3. The attached wallboard shall be installed with correct plate arrangement and flat surface; The installation of embedded wallboard shall be flat, the upper and lower lap joints shall adopt tongue and groove joints, and the outer panel shall be lapped downward, and the lap length shall not be less than 15mm.
4、活动房内电器线路应采用PVC管(槽)明敷,布线整齐美观;电器配置符合设计要求;线路无绝缘老化及接长使用。
4. The electrical circuit in the activity room shall be laid in PVC pipe (slot) in an open manner, and the wiring shall be neat and beautiful; The electrical configuration meets the design requirements; The line is free of insulation aging and extension.
5、防火:防火间距应符合设计和规范要求,消防通道应通畅;消火栓、灭火器配置符合设计要求,布局合理;厨房等用火场所防火隔热措施应;金属面夹芯板氧指数不低于32,木地板等可燃材料应做防火处理。
5. Fire prevention: the fire prevention spacing shall meet the design and specification requirements, and the fire passage shall be unobstructed; The configuration of fire hydrants and fire extinguishers meets the design requirements and the layout is reasonable; Fire prevention and thermal insulation measures for kitchen and other fire sites shall be; The oxygen index of metal faced sandwich panel shall not be lower than 32, and combustible materials such as wood floor shall be subject to fire prevention treatment.
6、防雷:防雷接地设置符合设计和规范要求;接地电阻应检测合格。
6. Lightning protection: the lightning protection and grounding settings meet the design and specification requirements; The grounding resistance shall pass the test.
7、防腐:钢构件应油漆完好、无锈蚀,外露螺栓防护得当;强腐蚀环境下的防腐措施符合设计要求;活动房周边应排水通畅,无积水,不准放杂物。
7. Anti corrosion: steel members shall be painted in good condition without corrosion, and exposed bolts shall be properly protected; The anti-corrosion measures in strong corrosive environment meet the design requirements; The periphery of the activity room shall be drained smoothly without ponding and sundries are not allowed.
The wonderful content of this article is provided by Jinan Caigang plank house. There are many wonderful contents on this website. You can click to enter more contents: http://www.lxcaigang.com We have special customer service to answer your questions